Articles available: 109

CONTINUING SCIENTIFIC EDUCATION IN VETERINARY MEDICINE

Monday, 21 November 2022

Smartwatches exhibit high accuracy in evaluating heart rate and peripheral oxygen saturation in cats

  • GF5xp and AppW6 exhibited high accuracy in evaluating HR and SpO2 in cats
Rate this item
(0 votes)

CatThe aim of this study was to evaluate the accuracy for 2 smartwatches with oximetry technology and optical wrist heart rate (HR) or single-lead Electrocardiography (ECG) technology (Fenix 5X Plus [GF5xp], Garmin Ltd and Apple Watch 6 [AppW6], Apple Inc, respectively) versus reference methods (ECG and transmittance pulse oximetry [TPO], respectively) in measuring HR and peripheral oxygen saturation of hemoglobin (SpO2) in cats.

10 male client-owned cats aged 8 to 12 months and weighing 3.2 to 4.5 kg were included. All cats that were presented for elective castration at the Atatürk University Animal Hospital between March 10 and April 15, 2022, were considered for enrollment. Monitoring of HR and SpO2 during anesthesia was performed with a 3-lead ECG and transmittance pulse oximetry, respectively, connected to a multiparameter monitor (reference methods) along with a GF5xp and a AppW6. Agreement between reference methods and the smartwatches were assessed by the Bland-Altman plot.

To read the complete article, you must log in with your EGO account.

Written by
Antonio Maria Tardo Med Vet PhD Student

Read 45 times Last modified on Thursday, 17 November 2022 17:55

vetchannel nero

VETCHANNEL.IT
Professional training on demand
when you want, where you want.